WebAug 20, 2012 · To check the power supply environmental status, use the following operational mode command: user@host> show chassis environment Sample Output For M5, M10, M20, and M40 routers: user@host> show chassis environment Class Item Status Measurement Power Power Supply A OK Power Supply B Absent [...Output … WebMay 22, 2024 · To view critical alarms specifically, use the show facility-alarm status critical command: Router# show facility-alarm status critical System Totals Critical: 2 Major: 0 Minor: 1 Source Severity Description [Index]----- ----- -----Power Supply Bay 0 CRITICAL Power Supply/FAN Module Missing [0] xcvr container 0/0/0 CRITICAL Transceiver …
Show power usage for devices - Cisco Community
WebAug 20, 2024 · 1. Is the "System Power Used" for the stack master switch or the stack as a whole. It is for the master switch. If you want to see the power usage on all switches in the stack, run "sh power inline". 2. I'd like to be able to pull this information via SNMP if possible. Would anyone know which MIB would give me this info. WebJun 4, 2024 · ciscoasa> show alarm settings Power Supply Alarm Disabled Relay Disabled Notifies Disabled Syslog Disabled Temperature-Primary Alarm Enabled Thresholds MAX: 92C MIN: -40C Relay Enabled Notifies Enabled Syslog Enabled Temperature-Secondary Alarm Disabled Threshold Relay Disabled Notifies Disabled Syslog Disabled Input-Alarm … rbc visa credit card cash advance fee
Show Commands - Cisco
WebJul 24, 2024 · Effective from Cisco IOS XE Everest 16.6.1, on RSP3 module, alarm notification is enabled on 900 watts DC power supply. There are 2 input feeds for 900 watts DC power supply, if one of the input voltage is lesser than the operating voltage, critical alarm is generated for that particular feed and clears (stops) once the voltage is restored … WebOct 4, 2024 · The threshold {restart voltage shutdown voltage} keywords and arguments were added to the env power-supply command. Release 3.4.1. The threshold {restart voltage shutdown voltage} keywords and arguments were removed, and the command was changed to env power-supply disable . Power supply monitoring was enabled by … WebFeb 22, 2024 · Power supply modules monitor their internal temperature, voltage, and current load and share the status with the RP. Based on the status the RP generates an alarm and logs the appropriate warning messages on the console. The following figure shows the status indicators for the power module. Figure 4. Cisco ASR 9902 DC PSU 1 … rbc visa gold preferred travel insurance